Epilog Knowledge Base - Support Center
Imagine. Design. Create.
Support Center > Knowledge base> Article: Power Supply Replacement (Meanwell) in the Epilog Helix

Power Supply Replacement (Meanwell) in the Epilog Helix

Article ID: 12269 Print
Question
How do I replace a Meanwell Power Supply in the Helix?

Answer

Power Supply Replacement (Meanwell) in the Epilog Helix

Machine Type:    Epilog Helix

Tools Needed:     

  • Philips Head Screw Driver
  • 5/16 nut driver
  • Wire Cutters 

Equipment:

 Intro:

     This procedure details steps to replacing the Meanwell power supply in the Helix. Before starting on this procedure, unplug the power cord from the machine. 

Procedure:

  1. Remove the back service panel.
  2. Disconnect three of the electrical leads.
    a.  Disconnect the connectors holding the green with yellow stripe, black, and white lead. 
    b.  Disconnect the farthest left connector holding the black and red lead.
    c.  Disconnect the connector holding red and black lead. This connector is directly under the left edge of the laser tube.  

  3. With a Philips head screw driver, unscrew the green screws located on each side of the power supply.

  4. Replace the Meanwell power supply.

  5. Reconnect the three electrical connectors.
    a.  Reconnect the connector with the green with yellow stripe, black, and white lead.  There are two leads containing these wires, connect only the longer of the two.


    b.  Reconnect the two connectors holding the red and black leads. The longer of the leads goes to the farthest left connector. The shorter lead connects to the lead from the laser tube.

  6. Tuck in the wires under the power supply and replace the back service panel. 

If you have any questions, please contact Epilog’s Technical Support

Phone   303.215.9171
Fax       303.531.7594
E-Mail    tech@epiloglaser.com


related articles

Article Details
12227 Created on: Nov 04, 2011
Date updated: Jul 13, 2023
Posted in: Epilog Helix

Poor
Outstanding