Auto Focus Plunger Replacement on the Mini/Helix
Machine Type: Epilog Mini 18/24, Helix
Tools Needed:
- Small screw driver
- 5/64 Allen wrench
Intro:
This procedure details steps to replacing the auto focus plunger on the Legend Mini and Helix machines. Before starting on this procedure, lower the engraving table a few inches and then turn off the machine. Please consult the exploded drawing of the X-carriage assembly for part names.
Procedure:
- Remove the gray X-beam cover.
- Remove the 5/64 hex screw from the Auto Focus plunger shaft.
- Replace the auto focus plunger with a new plunger.
- Put the Auto focus plunger into the spring and gently push up.
- Tighten the 5/64 hex screw on the Auto focus plunger shaft.
- Replace the gray X-beam cover.
For a larger image of the exploded drawing of the X-Axis Carriage, click here.
If you have any questions, please contact Epilog’s Technical Support
Phone 303.215.9171
Fax 303.531.7594
E-Mail tech@epiloglaser.com